The AC-240 monitors one inductive loop for vehicle detection. Its presence and pulse outputs can be connected to a compatible barrier or gate controller. DIP switches adjust sensitivity, frequency and output behaviour.
Technical specifications
| Product type | Single-channel inductive loop detector |
|---|---|
| Loop inputs | 1 |
| Power supply | 200–260 V AC, 50 Hz |
| Outputs | Presence relay and pulse relay |
| Relay contact rating | 0.5 A at 220 V AC |
| Loop inductance | 15–1500 µH |
| Sensitivity | 8 selectable levels: 0.01–2% |
| Frequency selection | 2 settings |
| Pulse duration | 0.2 s or 1 s |
| Connection | 11-pin connector |
| Dimensions (H × W × D) | 80 × 40 × 79 mm, excluding socket |
| Weight | 0.28 kg |