DART BATTERY uses a battery-powered transmitter and a wired receiver to detect interruption of an infrared beam. The optics can be aligned to suit the installation. The receiver provides a selectable NO/NC contact for connection to a compatible automation controller.
Technical specifications
| Set | 1 transmitter and 1 receiver |
|---|---|
| Maximum range | 18 m |
| Transmitter power supply | 1 × 1.5 V alkaline AA battery |
| Receiver power supply | 12/24 V AC/DC |
| Transmitter current draw | 0.30 mA max. |
| Receiver current draw | 25 mA max. |
| Relay output | NO or NC, jumper selectable |
| Relay contact rating | 1 A max. at 30 V DC |
| Operating temperature | −10 to +55 °C |
| Operating codes | A/B selectable |
| Optical adjustment | 180° |