The VEK MNH2-R24-C monitors two inductive loops and provides one relay output per channel. It supports presence and direction detection in vehicle-access installations. Configuration is available through DIP switches, with extended settings and diagnostics through the USB service interface.
Technical specifications
| Manufacturer order number | 5019 |
|---|---|
| Detection channels | 2 |
| Power supply | 10–30 V DC or 10–26 V AC, SELV |
| Power consumption | 2 W max. |
| Outputs | 1 NO relay contact per channel; signal invertible |
| Relay limits | 48 V AC/DC max.; 2 A max.; 60 W / 125 VA max. |
| Loop inductance | 20–700 µH; recommended 100–300 µH |
| Loop frequency | 30–130 kHz |
| Sensitivity adjustment | 0.01–0.64% Δf/f in 4 DIP-switch steps; extended software settings |
| Loop feeder cable | Up to 200 m |
| Configuration / diagnostics | DIP switches and USB service software |
| Mounting | DIN rail |
| Housing | ABS, blue RAL 5001 |
| Protection rating | IP20 |
| Operating temperature | −37 to +70 °C |
| Dimensions (W × H × D) | 22.5 × 79 × 81 mm, without terminals |
| Weight | 160 g |